Inspection History: ELECTRIC - FINAL
Permit Number - T08EL01004
Inspection Description - ELECTRIC - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NEED TO IDENTIFY ALL BREAKERS ONCE POWER IS ENERGIZED |
|
06/05/2008 | ELECTRIC - FINAL | Denied | 1) SECURE LIQUID TIGHT 12" FROM DISCONNECT BOX CONDENSOR 2) GFCI PROTECT EXTERIOR OUTLETS WEATHERED COVERS 3) PROVIDE GAS AND WATER BONDS 4) COVER EXTERIOR JUNCTION BOX 5) GFCI PROTECT KITCHEN OUTLETS 6) SMOKE DETECTORS ALL BEDROOMS AND HALLS 7) PROVIDE ACCESS TO PANEL 8) GFCI PROTECT OUTLETS IN LAUNDRY ROOM |