Permit: T08EL00941

Parcel: 136331070


Addresses:

9348 E 39TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/01/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/27/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. USE WHITE TAPE TO IDENTIFY NEUTRAL WIRE BETWEEN PANEL AND J-BOX
2. USE MYERS HUB OR WATERPROOF NUTS ON CONNECTORS AT TOP OF PANEL
3. NEED GROUND WIRE FROM PANEL TO JUNCTION BOX. IF INSULATED NEEDS TO BE COLOR CODED GREEN
4. WHEN CONNECTING COPPER TO ALUMINUM USE APPROVED CONDUCTORS SO ALUMINUM AND COPPER DON'T TOUCH. SPLIT BOLT WITH BRASS SPACER IS MOST COMMON.
06/13/2008 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) OK TO ENERGIZE
2) RECALL WHEN COMPLETE
3) BOND GAS AND WATER