Permit: T08EL00884

Parcel: 10602282B


Addresses:

38 W PRINCE RD #20

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/30/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/24/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GFI AT HALL BATH NOT PROTECTED ON GFI CIRCUIT
06/20/2008 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER TRACY
06/19/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GFI AT HALL BATH HAS OPEN GROUND
06/16/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 7 MISSING COVER PLATES
2) HAZARDOUS ELECTRICAL ROMEX SPLICES WATER HEATER ROOM. MAKE UP CONNECTIONS IN APPROVED BOXES
3) ROMEX CONNECTOR FLOURESCENT LIGHT FIXTURE MASTER BATH
4) GFCI PROTECT MASTER BATH OUTLET
5) LABEL CIRCUITS SUB PANEL
6) MISSING SMOKE DETECTOR EAST BEDROOM WEST SIDE OF DOOR
7) SECURE ALL STEPS TO UNIT
06/06/2008 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
05/20/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DOESN'T LOOK TO BE COMPLETELYB SET UP, BLOCKING AT PERIMETER, LANDING STAIR AT REAR SLIDING DOOR AND DOOR
2) MISSING ELECTRICAL FIXTURES INSIDE
3) WILL NEED TO INSPECT FOR SMOKE DETECTORS/GFCI RECEPTACLES AT KITCHEN
4) COVERS OFF AC/HEAT UNIT AT REAR OF HOME
5) BURNED RECEPTACLE IN REAR BEDROOM
6) MISSING SWITCHES THROUGHOUT
7) SUB PANEL, NEED A BUSHING FOR POWER CORD, A CORD RESISTANT, A GROUND BUSS BAR
8) SINGLE POLE 30 AMP BREAKERS IN SUB PANEL, TWO WIRES RUN TO TWO 30 AMP BREAKERS, UNLABELED CIRCUITS, CLEAN UP SUB PANEL
9) ADDRESS REQUIRED ON PEDESTAL