Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/20/2008 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 05/19/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PERMITS 2) ITEM #6 HAS NOT BEEN MET |
|
| 05/09/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SMOKE ALARMS MUST BE MIN. 3' AWAY FROM DUCTS 2. ALL COVER PLATES MUST BE ON RECEPTACLES 3. SMOKE DETECTOR MASTER BEDROOM NOT WORKING 4. NEED SMOKE IN HALLWAY 5. GAS LINE NEEDS TO BE BONDED 6. CARPORT ENCLOSURE NEED TO SHOW VERIFICATIONS OF PERMITS (NOT PERMITTED) 7. DRYER MUST BE ON DEDICATED CIRCUIT 8. SERVICE PANEL LOCKED -- NO ACCESS |