Permit: T08EL00763

Parcel: 119044610


Addresses:

3625 S 7TH AV #02

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/07/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO ACCESS 1:40 PM
RECALL
06/26/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. LARGER ADDRESS NUMBERS
2. GAS BOND
3. BLANK COVERS FOR UNUSED SPACES AT SUB-PANEL
06/25/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE BLANK COVERS UNUSED SPACES SUB PANELS/IDENTIFY ALL CIRCUITS
2) PROVIDE GAS BOND
3) POST UNIT NUMBERS WITH 4" NUMBERS
4) PROVIDE ACCESS TO UNIT
05/01/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DEAD FRONT EXTERIOR SUB PANELS LABEL CIRCUITS
2) SECURE SUB PANELS TO WALL EXTERIOR
3) POST PERMANENT UNIT NUMBERS
4) INSTALL REAR LIGHT FIXTURE
5) LABEL ALL UNITS METAL TAG WITH RAISED LETTERS MAIN SERVICE PANEL 4 PACK
6) PROVIDE GAS BOND AND WATER BOND #4 ?
7) GFCI PROTECT KITCHEN OUTLETS AT SINK
8) GFCI PROTECT BATH OUTLET
9) INSTALL GLOBE BATH LIGHT FIXTURE
10) BEDROOM WINDOWS DO NOT OPERATE FOR EGRESS
11) WEATHERED BOX COOLER