Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/07/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ACCESS 1:40 PM RECALL |
|
| 06/26/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. LARGER ADDRESS NUMBERS 2. GAS BOND 3. BLANK COVERS FOR UNUSED SPACES AT SUB-PANEL |
|
| 06/25/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE BLANK COVERS UNUSED SPACES SUB PANELS/IDENTIFY ALL CIRCUITS 2) PROVIDE GAS BOND 3) POST UNIT NUMBERS WITH 4" NUMBERS 4) PROVIDE ACCESS TO UNIT |
|
| 05/01/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DEAD FRONT EXTERIOR SUB PANELS LABEL CIRCUITS 2) SECURE SUB PANELS TO WALL EXTERIOR 3) POST PERMANENT UNIT NUMBERS 4) INSTALL REAR LIGHT FIXTURE 5) LABEL ALL UNITS METAL TAG WITH RAISED LETTERS MAIN SERVICE PANEL 4 PACK 6) PROVIDE GAS BOND AND WATER BOND #4 ? 7) GFCI PROTECT KITCHEN OUTLETS AT SINK 8) GFCI PROTECT BATH OUTLET 9) INSTALL GLOBE BATH LIGHT FIXTURE 10) BEDROOM WINDOWS DO NOT OPERATE FOR EGRESS 11) WEATHERED BOX COOLER |