Permit: T08EL00756

Parcel: 10602282B


Addresses:

38 W PRINCE RD #39

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/13/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/12/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OPEN GROUND AT RECEPTACLE ON NORTH WALL LIVING ROOM AND KITCHEN COUNTER NEXT TO REFRIDGERATOR
2) ALL RECEPTACLES ON KITCHEN COUNTER MUST BE GFI
3) GFI AT MASTER BATH NOT WORKING
4) RECEPTACLE ON WEST KITCHEN WALL HAS HOT AND GROUND REVERSED
5) NO SWITCH TO LIGHT OVER SINK
6) OPEN GROUND AT OUTSIDE GFI
04/30/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SMOKE DETECTORS REQ'D IN EACH BEDROOM AND OUTSIDE OF BEDROOMS
2. GFI PROTECTED OUTLETS REQ'D IN KITCHEN AND BATHROOM
3. ROMEX AT INTERIOR PANEL IN CLOSET MUST BE PROTECTED FROM PANEL TO CEILING
4. INSTALL ALL LIGHT FIXTURES & GLOBES
5. INSTALL STAIRWAY ON NORTH DOOR

COMPLY & RECALL FOR INSPECTION