Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T08EL00737
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/12/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 05/01/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED GFI BATHROOM RECEPTACLE 2. OPEN BULB LIGHT FIXTURE NOT ALLOWED IN CLOTHES CLOSET 3. REPLACE PAINTED OVER DEVICES 4. SMOKE DETECTORS TO BE 36" MIN. AWAY FROM VENTS AND MIN. 4" AWAY FROM CEILING 5. PROVIDE GFI FOR RECEPTACLE BEHIND RANGE 6. REPLACE CRACKED DEVICE COVERS 7. IDENTIFY PANEL DIRECTORY 8. PROVIDE ACCESS TO SERVICE 9. PROVIDE CONNECTOR FOR WIRING INTO HOOD NO GROUND? |
|
| 04/29/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE ACCESS TO INTERIOR AND TO SERVICE |