Permit: T08EL00701

Parcel: 10409139B

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T08EL00701

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/08/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/05/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
STILL NEED TO COMPLETE #1, #2, #4 FROM ORIGINAL INSPECTION -- A FEE WILL BE CHARGED IF NOT CORRECT NEXT INSPECTION.
05/01/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
DO NOT CALL BEFORE ALL CORRECTIONS COMPLETE
04/25/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NEED SMOKE DETECTORS EACH BEDROOM AND HALLWAY
36" AWAY FROM VENTS, BETWEEN 4" & 12" IF ON WALL
2. NEED GFI RECEPTACLES FOR KITCHEN COUNTER RECEPTACLES
3. OPEN BULB TYPE LIGHT FIXTURE NOT ALLOWED IN CLOTHES CLOSET
4. IDENTIFY PANEL DIRECTORY
5. NEED CONNECTOR FOR DISPOSAL CORD