Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/14/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 05/12/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RECEPTACLE AT CARPORT NEEDS TO BE GFI WITH APPROVED WEATHER COVER |
|
| 05/02/2008 | ELECTRIC - FINAL | Cancelled | IVRS - RI canceled | |
| 04/30/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* N.EAST BEDROOM EMERGENCY EXIT BLOCKED WITH UNPERMITTED CARPORT ENCLOSURE OBTAIN PERMITS FOR ENCLOSURE AND PROVIDE PROPER EXIT FROM BEDROOM TO OUTSIDE |
|
| 04/29/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. LABEL ALL CIRCUITS MAIN SERVICE PANEL 2. GFCI PROTECT LAUNDRY OUTLET @ SINK 3. SECURE EXTERIOR SWITCH TO WALL REAR PORCH 4. PHYSICAL PROTECTION REQUIRED EXTERIOR ROMEX UNDER 7' |
|
| 04/28/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) RECEPTACLE MISSING COVER PLATE AT FURNACE 2) NEED BUBBLE COVER ? RECEPTACLE FOR A/C UNIT AT FAMILY ROOM/LIVING ROOM-WILL REINSPECT BOTH ITEMS AT ELECTRICAL FINAL |
|
| 04/23/2008 | ELECTRIC - FINAL | Cancelled | IVRS - RI canceled | |
| 04/23/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SERVICE PANEL NEEDS KNOCKOUT COVERS ON DEAD FACE FOR ALL UNUSED OPENINGS 2. NEED TO MOUNT RANGE HOOD AND TAKE WEIGHT OFF OF CONDUCTORS (WIRING) 3. NEED TO BLANK OR COMPLETE RECEPTACLE FOR RANGE 4. ALL WALL RECEPTACLES NEED TO HAVE WALL PLATE COVERS 5. MISSING SMOKIES IN HALLWAY AND BEDROOMS 6. COOLER MOTOR SWITCH NEEDS TO BE SECURED 7. NEED TO BE ABLE TO VERIFY GROUND RODS |