Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T08EL00571
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/02/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
05/01/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE T08EL00573 |
|
04/30/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. BONDING CONDUCTOR TO METER BASE UNDERSIZED - NEC 250.102C 2. CLAMPS IN GROUND TO DIRECT BURIAL - NEC 110.3B |
|
04/17/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. GROUNDING ELECTRODE CONDUCTOR TO TERMINATE AT GROUNDED TERMINAL - DO NOT USE EQUIPMENT AS PATH 2. GROUNDING ELECTRODE CONDUCTOR TO BE PER 250.64(D) |