Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/10/2008 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 04/07/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UNLESS INSTALLATION INSTRUCTIONS SHOW DIFFERENT, SMOKE DETECTORS ARE TO BE LOCATED BETWEEN 6" AND 12" OF THE CEILING WHEN LOCATED ON A WALL 2) I SEE WHERE YOU BONDED THE GAS AND WATER TOGETHER AT THE WATER HEATER. I AM UNABLE TO LOCATE THE WATER BOND TO THE PANEL |
|
| 03/28/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL SMOKE DETECTORS ALL BEDROOMS AT LEAST 6" FROM CORNERS AND AT LEAST 3' FROM REGISTERS 2) INSTALL GFI RECEPTACLE HALL BATH 3) EXTERIOR RECEPTACLES TO BE GFI WITH WEATHER PROOF COVERS 4) BOND GAS AND WATER LINES |