Permit: T08EL00492

Parcel: 136211300


Addresses:

7352 E 42ND ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
04/10/2008 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
04/07/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UNLESS INSTALLATION INSTRUCTIONS SHOW DIFFERENT, SMOKE DETECTORS ARE TO BE LOCATED BETWEEN 6" AND 12" OF THE CEILING WHEN LOCATED ON A WALL
2) I SEE WHERE YOU BONDED THE GAS AND WATER TOGETHER AT THE WATER HEATER. I AM UNABLE TO LOCATE THE WATER BOND TO THE PANEL
03/28/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL SMOKE DETECTORS ALL BEDROOMS AT LEAST 6" FROM CORNERS AND AT LEAST 3' FROM REGISTERS
2) INSTALL GFI RECEPTACLE HALL BATH
3) EXTERIOR RECEPTACLES TO BE GFI WITH WEATHER PROOF COVERS
4) BOND GAS AND WATER LINES