Permit: T08EL00466

Parcel: 134070780


Addresses:

8338 E JULIA ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/02/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
04/30/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. HALL BATH RECEPT DOESN'T TEST
2. GARAGE RECEP TO BE GFI
3. RECEPS SE BEDROOM INOP.
4. 3 PRONG RECEPS NEED TO BE GROUNDED OR ON GFI BREAKERS
04/11/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL ALL DEVICES AND COVERS
2) PROTECT RANGE WIRE
3) RECEPTACLES REQUIRED WITHIN 2' OF ANY BACK DIEMENSION ON KITCHEN COUNTER AND ON ANY COUNTER 12" WIDE OR WIDER
4) WITH MAJOR REMODELING, SMOKE DETECTORS ARE REQUIRED IN EACH BEDROOM AND IN HALLWAYS OR ROOMS OUTSIDE OF BEDROOMS, ALL INTER-CONNECTED