Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 04/21/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 04/15/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CANNOT SEE INTO METER SECTION 2. GROUND RODS TO BE MIN. 6' APART 3. BOND RISER & OFFSET NIPPLE PER NEC 250.92 4. PANEL DOOR TO OPEN 90 DEG. 5. NEED DETAILED PANEL DIRECTORY NEC 408.4 6. CANNOT VERIFY WATER BOND 7. GENERATOR TO BE SIZED FOR LOAD TO BE CARRIED - NEC 702.5 8. NEUTRALS & GROUNDS TO BE SEPARATE @ PANEL 9. INSTALL BREAKERS LISTED FOR USE IN PANEL 10. ELECTRICIAN TO BE ON SITE TO OPEN GENERATOR |