Permit: T08EL00453

Parcel: 138143580


Addresses:

534 W HATFIELD ST

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/21/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOTE 4 & 5 FROM PREVIOUS
2) REPLACE WINDOW FOR EGRESS N.E. CORNER ABOVE 44" S14 HEIGHT DOES NOT MEET OPENING 5.7 SQUARE FT.
03/21/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXPOSED WIRING BATH LIGHT FIXTURE AND HALLWAY FIXTURE
2) INSTALL SMOKE DETECTOR HALLWAY AND REAR BEDROOM
3) PROTECT ALL WIRING STORAGE ROOM UNDER 7" HEIGHT
4) SECURE GROUND WIRE TO BUILDING MAIN SERVICE
5) LABEL CIRCUITS MAIN PANEL
6) PROVIDE PROOF ALL ADDITIONS AND REAR PORCH UNDER PERMIT. OVERSPANNED RAFTERS REAR PORCH APPROVED DRAWINGS
7) EXPOSE SECONDARY GROUND ROD
8) PROVIDE GAS WATER BONDS