Permit: T08EL00365

Parcel: 140061630


Addresses:

3838 E NEBRASKA SV

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
10/06/2008 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
08/13/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/06/2008 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PERMIT REQUIRED FOR STORAGE BUILT ON EAST SIDE ON PROPERTY LINE, SUBMIT 2-COMPLETE SET OF DRAWINGS TO DEVELOPMENT SERVICES DEPT. FOR PERMITS
2) COMB AND RELIEF VENTS REQUIRED FOR WATER HEATER
3) 6" MIN. CLEARANCE FROM COMBUSTIBLES REQUIRED AT WATER HEATER SINGLE WALL VENT
4) BOND GAS LINE
5) BUBBLE COVERS REQUIRED AT EXTERIOR OUTLETS
6) GFI PROTECTED OUTLETS REQUIRED IN BATHROOM LAV AND KITCHEN
7) CHECK OFFICE FILES TO VERIFY WEST BATH, BEDROOM ARE PERMITED-FURNACE ROOM DOOR NOT ALLOWED TO OPEN INTO BATHROOM FURNACE ROOM DOOR MUST BE SEALED TIGHT
8) GAS DRYER SHALL NOT BE INSTALLED IN BATH, BEDROOM AREA
9) HIRE ELECTRICIAN NUMEROUS ELECTRICAL VIOLATIONS SMOKE ALARMS MISSING THRU-OUT