Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 02/26/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CANNOT USE SJ CORD FOR PERMANENT WIRING NEEDS TO BE REMOVED FROM CABINET & UNDER SINK 2. HAVE OPEN WIRES WHER EXHAUST HOOD WAS 3. INSTALL MISSING WALL PLATES 4. HAVE OPEN BOXES WHERE LIGHT FIXTURES WERE 5. MARK ADDRESS ON SERVICE 6. KITCHEN & BATHROOM RECEPTACLES TO BE GFI PROTECTED 7. INSTALL SMOKE DETECTORS IN BEDROOMS PER MANUFACTURES INSTRUCTIONS 8. HALLWAY SMOKE DETECTOR TO BE OPERATIONAL 9. CLOTHES CLOSET LIGHTS TO BE 100% ENCLOSED OR REMOVED 10. MISSING LIGHT IN HALL BATH 11. OUTDOOR RECEPTACLES TO BE GFI PROTECTED 12. RECALL WHEN READY |