Permit: T08EL00152

Parcel: 136190560


Addresses:

3318 S MEAD AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T08EL00152

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/21/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
02/08/2008 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
02/06/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SERVICE CONDUCTORS TO BE INSTALLED 2/0 COPPER
OR 4/0 AL
2. INSTALL BREAKERS LISTED FOR USE IN SIEMENS PANEL
3. BOND GAS & WATER PIPING
4. INSTALL METER SECTION FOR OVERHEAD POSITION. SEE INSTRUCTIONS
5. SEAL OPENING WHERE WIRES ENTER BACK OF PANEL WITH NON-COMBUSTIBLE MATERIAL
6. NEED DETAILED PANEL DIRECTORY
7. SECURE MAST TO BUILDING SURFACE
8. OK GROUND RODS