Permit: T08EL00142

Parcel: 11108201F

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/28/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
#6
1. KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED
2. INSTALL SMOKE DETECTORS IN BEDROOMS PER MANUFACTURES INSTRUCTIONS
3. BLANK OPEN BREAKER POSITIONS @ PANEL
4. HAVE DOUBLE TAPPING OF BREAKERS IN PANEL

#F
1. STRAP EMT AT BACK PORCH
2. DRYER RECEPTACLE TO BE IN WEATHERPROOF BOX WITH WEATHERPROOF COVER
3. INSTALL NEW WEATHERPROOF COVER @ GFI RECEPT BACK PORCH
4. KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED
5. REPLACE BATTERIES IN SMOKE DETECTORS/TO BE OPERATIONAL
6. SMOKE DETECTORS TO BE MIN. 3' FROM VENT