Permit: T08EL00118

Parcel: 136050070


Addresses:

8853 E 29TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
02/19/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
02/12/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. STILL NEED DETAILED PANEL SCHEDULE
2. CANNOT TERMINATE #4 & #6 GROUND UNDER ONE LUG
3. PERMIT FOR A/C UNIT TO BE RENEWED AND INSPECTIONS TO BE SCHEDULED & DONE
4. PLEASE HAVE ABOVE ITEMS CORRECTED BEFORE NEXT INSPECTION TO AVOID REFEE
01/29/2008 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
CANCELED BY CONTRACTOR
01/25/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL GROUND RODS MIN. 6' APART
2. BOND GAS & WATER PIPING
3. VERIFY PERMIT FOR NEW A/C UNIT. PROVIDE COPY OF PERMIT NEXT INSPECTION
4. INSTALL LISTED MAST BRACING
5. PROVIDE DETAILED PANEL DIRECTORY
6. SEAL OPENING IN BACK OF PANEL WHERE WIRES ENTER WITH NON-COMBUSTIBLE SEALANT
7. METER SEALED & SERVICE ENERGIZED PRIOR TO INSPECTION - CANNOT SEE INTO METER SECTION
8. IS DRYER GAS OR ELECTRIC? IF ELECTRIC SHOULDN'T IT BE FED WITH #10 ON 2 POLE 30