Inspection History: ELECTRIC - RECONNECT
Permit Number - T08EL00040
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/10/2008 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
01/09/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED 2. BATHROOM RECEPTACLES TO BE GFI PROTECTED THIS INCLUDES RECEPTACLE IN LIGHT FIXTURE 3. CLOTHES CLOSET LIGHT FIXTURES TO BE 100% ENCLOSED 4. SMOKE DETECTORS NOT INSTALLED PROPERLY. TO BE 4"-12" DOWN FROM CEILING, 3' FROM VENT 5. RECALL WHEN READY |