Permit: T08EL00037

Parcel: 125110810


Addresses:

3653 E 2ND ST #214


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T08EL00037

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/15/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/14/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SECURE BASEBOARD HEATER TO WALL
2. RECEPTACLES TO BE WIRED AS LISTED -
DO NOT "STAB" 12 GA WIRE
3. TIGHTEN ALL CONNECTIONS
01/11/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NEED UNIT # CORRECTLY IDENTIFIED @ SERVICE
2. INSTALL SMOKE DETECTORS IN BEDROOM AND LIVING ROOM PER MANUFACTURES INSTRUCTIONS MINIMUM 36" FROM VENTS
3. PROVIDE GFI PROTECTION FOR KITCHEN COUNTER AND BATHROOM RECEPTACLES
4. SECURE BASEBOARD HEATERS TO WALL AND
REPLACE T-STAT KNOBS
5. REPLACE PAINTED OVER DEVICES