Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1) DOOR UNLOCKED-FRONT UNIT EAST UNIT |
|
| 01/24/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS 2:27 PM 2) RECALL |
|
| 01/22/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SMOKE DETECTORS NOT INSTALLED PROPERLY. MOUNTED TO LOW ON WALL NEED TO BE MIN. 4" TO MAX. 12" DOWN 2. INSTALL MISSING PLATE ON RECEPTACLE IN KITCHEN 3. IS SINGLE RECEPTACLE OUTSIDE BACK DOOR GFI PROTECTED 4. NEED PANEL DIRECTORY |
|
| 01/04/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED SMOKE DETECTORS EACH BEDROOM AND HALLWAY ALL NEW 2. PROVIDE GFI PROTECTION FOR KITCHEN COUNTER, BATHROOM AND EXTERIOR 120V RECEPTACLES 3. HAVE OPEN WIRING IN WALL AT HOOD LOCATION 4. NEED W.P COVER FOR RECEPTACLE UNDER SERVICE 5. HAVE OPEN WIRING UNDER SINK 6. IDENTIFY PANEL DIRECTORY 7. SERVICE TO BE SECURED TO STRUCTURE |