Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08CM04020
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/19/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
09/15/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE TEMPERING FOR PUBLIC USE 2) LAVS NOT TO EXCEED 110 DEGREES 3) PROVIDE 2 FANK PATTERN CLEANOUT COVERS IN POOL AREA DOCK |
|
08/30/2011 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) PROVIDE BACKFLOW CERTS 2) PROVIDE SPECIALIZATION AND BACTERIA REPORTS 3) CORRECT VENT ON ROOF 3RD FLOOR: 1) PROVIDE HAMMER ARRESTORS LAUNDRY ? 2) EXPOSE TRAP PRIMER LAUNDRY 2ND FLOOR: 1) PROVIDE VACUUM BREAKER AT HOSE BIB AT SOFTNER AND TERMINATE OVERFLOW DRAINS WITH 1" AIR GAP AT FLOOR SINK 2) PROVIDE GRATE AT FLOOR SINK 1ST FLOOR: 1) COMPLETE ALL PLUMBING INSTALLS AT EXTERIOR 2) EXTERIOR COMPLETE ALL CLEANOUTS, HOSE BIB VACUUM BREAKERS 3) DWV THRU ROOF AT FUTURE OK PENDING PLAN 4) SOAP TEST BY CONTRACTOR OK 5) PROVIDE CORRECT VENT FOR WATER HEATER |
|
08/15/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CALL IN ALL PLUMBING INSPECTIONS THAT HAVE NOT BEEN APPROVED (03005, 03035 AND 03075) 2) PROVIDE REVISED CITY APPROVED PLAN FOR CHANGES TO WATER HEATER PIPING. THIS INSPECTION FOR SEDIMENT TRAPS AND WATER HEATER PIPING ONLY PER REVISED 8 1/2 X 11 DATED 5/19/11 JAMES R. MEYER TO BE CITY APPROVED 3) OK TO INSULATE WATER HEATER AREA |
|
08/11/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) LEVEL 4 FIXTURES WATER TEST OK 2) UNABLE TO VERIFY CW ON RIGHT 3) SHOWER HEADS AND TUB STOPPERS NOT YET INSTALLED |
|
08/10/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NEED TO VERIFY HOT AND COLD ? 2) CHECK SPEC FOR SEPERATE SOV FOR DW 3) AVIOD TRAPPING DW HOSE |
|
08/05/2010 | PLUMBING - FINAL | Prior to Final Inspectn | HOLD FINAL TILL RELEASE OF ASSURANCE ISSUED TO COT FROM YVONNE PCRWRD- 740-6733 |