Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T08CM04020
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/15/2011 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
03/30/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WATER TEST ON 2" CONDENSATE DRAIUS PIPING ON EXTERIOR TIED INTO 1" AND 3/4" FROM BLDG ABOVE GRADE TERMINATING AT DRY WALLS OK EXCEPT 2" COMBO ON NORTH WEST JUST BEFORE DRY WALL REPAIR LEAK THIS LOCATION. 1" CW TO POOL FILL OK EXPOSE A PORTION OF 1" CW TO TRASH ENCLOSURE TO TEST WITH WATER |
|
01/20/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) GW INTERCEPTOR WITH VENT AND PIPING TEST OK 2) LINT INTERCEPTOR WITH VENT AND PIPING TEST OK 3) CONDENSATE DRAINS STUB OUTS WEST SIDE OF BLDG TEST AND CONDENSATE TO INITIAL ON P1.0 OK |
|
01/13/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WATER TEST THRU ENTIRE BLDG INCLUDING HCS CONN. GW TO EXTERIOR ONLY FOR INITAL ON P1.0 |
|
01/10/2011 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) 8" SDR CONTINUES TO 10' FROM BLDG WITH CLEANOUT |
|
01/07/2011 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) NO VENT SHALL BE USED AS A DRAIN INSTALL FOR APPROVED PLAN. WATER TEST FROM INITIAL ON PGE P1.0 UPSTREAM UNDERGROUND ONLY OK |