Permit: T08CM03958

Parcel: 12212011A


Addresses:

1145 N VENICE AV 02

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
04/01/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
03/27/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
02/06/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
NEED REV. FOR ADDED MOP SINK
01/28/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. PIPING MODIFICATION RATHER THAN SYSTEM REPLACEMENT AS INDICATED ON PLAN IS
OK PER STANLEY D. ADAMS
2. PROVIDE REV. FOR MS
3. INSTALL COPPER TO MIN. STANDARDS
4. REAM ALL JOINTS
01/26/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. DWV W/TEST THRU ROOF
2. PLAN INDICATES ALL NEW PIPING WITH ONE CONN. TO EXISTING.
3. YOU HAVE LEFT MUCH OF THE EXISTING PIPING IN PLACE AND INSTALLED 16 TRANSITION FITTINGS AND OTHER OFFSET FITTINGS, MANY OF WHICH DO NOT HAVE A TEST ON THEM.
4. PROVIDE APPROVAL FROM YOUR ARCHITECT FOR THIS INSTALLATION AND REDLINE THIS CHANGE AS AS YOUR ADDITIONAL MS