Permit: T08CM03926

Parcel: 10511061R

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T08CM03926

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
02/11/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
OK TO COVER WALLS
CALL 03035 FOR CLOSET FLANGE INSPECTION
02/09/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
02/06/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. NO HEAT TRAP ON HOT SIDE OF WATER HEATER
2. NO SUPPORTS ON MEZZANINE PIPING
3. INSTALL INSULATION ON ALL PIPING (WATER)
4. UNDER FLOOR PIPING TO BE INSTALLED IN PRACTICAL ALIGNMENT. INSTALL HANGERS WITHIN 18" OF EACH
CHECK GRADE OF DRAIN PIPING COUPLING
MAY NOT SUPPORT ON COUPLING
3. FIX LEAKS AND RETEST
4. BEFORE FINAL REPLACE JIM CAP WITH BLIND PLUG