Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM03909
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/24/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/16/2009 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) #6 COMPLETED ON PREVIOUS INSPECTION OK |
|
02/24/2009 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSED HOLDOWN 1ST FLOOR BATH TO MASTER/SHEAR ABOVE, MARKED ON FLOOR 2) BLOCK #3 SHEARWALL, #4 BEDROOM 2ND FLOOR 3) HEADER SIZES NOT NOTED ? NON BEARING EXCEPT WALL LOAD 4) 2ND FLOOR WEST BEDROOMS TWO SHEARWALLS #3'S, BOTTOM PLATE 6" ON CENTER 16D'S 5) NEED SHEAR TRANSFER #3 2ND FLOOR AT EDGE OF CLEAR STORY (BEDROOM) 6) MISSED SHEAR NAILING EAST WALL AT WALK DECK 7) WALKED ROOF OK 8) F03A NOT SHOWN IN TRUSS DRAWINGS CROSS SECTION DELETED ON PLAN |