Permit: T08CM03840

Parcel: 12617138B


Addresses:

787 S ALVERNON WY

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
04/29/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
04/14/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) ALL UNDERGROUND WATER TEST ONLY OK PENDING RED LINE ON SITE
04/13/2009 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE FLOOR DRAIN WITH CORRECT CONNECTION AND CORRECT SIZE PER PLAN, THERE SHALL BE NO LEDGE OR RESTRICTION IN FLOW ON TAILPIECE
2. INSTALL PER APPROVED PLAN OR PROVIDE REDLINES ON SITE FOR CHANGES YOU HAVE MADE
3. A 3" DRAIN WOULD BE REQUIRED TO WET VENT THE FLOOR DRAIN WITH THE URINAL
4. NOTE: PLASTIC PIPING WILL NOT BE ALLOWED IN A RETURN AIR PLENUM UNLESS IT CAN MEET THE CORRECT SMOKE AND FLAME RATING
03/10/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*