Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T08CM03823
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/24/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
04/22/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. OK HANDLE PER PREVIOUS INSP. NOTES 2. GROUND 3/0 WIRE SIZE CUT AT BLOCK WALL, NEED TO REPLACE WITH IRREVERSIBLE TYPE SPLICE OR INSTALL NEW GROUND RODS, MUST REPAIR ASAP AS THIS SYSTEM IS UNSAFE WITHOUT. |
|
03/05/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK FOR USE OF UNITS AS PER DISCUSSIONS WITH LEERAY NEED TO BE COMPLETED BY 5/1/09 FOR HANDLES |
|
02/26/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
02/25/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* ALL ROOMS 2, 11, 12, 13 OK HANDLE ON DISCONNECT SERVICE NEED TO BE FIXED |
|
02/20/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK #2 ONLY - FINAL 1. MAIN DISCONNECT HANDLES MISSING - NEED TO REPLACE ASAP! 2. CONNECT GROUND FAULT PATH TO SERVICE |
|
02/19/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* #2: 1) BOND GAS PIPING 2) BEDROOM CIRCUITS TO BE ARC FAULT PER PLANS AND 210.2 3) MAKE UP BATH BAR PER INSTRUCTIONS AND PROTECT CONDUCTOR 4) ONLY ONE CONDUCTOR UNDER TERMINAL GROUND SCREW 5) MAIN SERVICE DISCONNECT INOPERABLE-NO HANDLE 6) NO GROUND PATH OBSERVED AT SERVICE |
|
02/02/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
01/27/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. OUTSIDE FIXTURES TO BE FLUSH TO WALL TO PREVENT WATER FROM ENTRY 2. INSTALL ALL DEVICES OR PLATES, HOOD AND FIXTURES |
|
01/23/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
01/21/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* #11 1. MISSING OUTSIDE LIGHT 2. MISSING LIGHT ENTRY HALL 3. MISSING COVER PLATES 4. CLEAN BREAKERS TO READ AMPACITY SETTINGS AND LABEL PANEL PER 408.4 |