Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/11/2009 | PLUMBING - INTERMEDIATE | Approved | ||
| 05/08/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/27/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* NEED TO REINSPECT FLANGES OK TO COVER ALL OTHER AREAS |
|
| 03/26/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SEAL JOINTS OF INSULATION W/APPROVED CEMENT PER MANUFACTURES INSTRUCTIONS 2. USE SOLID SUPPORTS IN WALL |
|
| 03/24/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SEE NOTE #8 ON PO.1 PLUMBING SPEC's - NOT INSULATED PER PLAN 2. SUPPORT HORIZONTAL PVC IN WALLS |
|
| 03/20/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. COPPER SHALL NOT BE BENT OR STRAINED 2. HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 3. PROTECT PVC FROM METAL STUDS 4. PVC TO BE SUPPORTED AT CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS 5. VERTICAL PVC TO BE SUPPORTED 6. NO PROVISION MADE FOR INSULATION 7. USE CORRECT SIZE ISOLATORS 8. OK TO INSULATE HOT |