Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T08CM03811

Parcel: 11012007B


Addresses:

5151 E GRANT RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/11/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
01/21/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSTALL BRANCH TAILPIECES PER LISTING (VERTICALLY)
ONLY ONE SLIP NUT ALLOWED DOWNSTREAM OF P-TRAP
(INDIRECT WASTE IS CONNECTED DOWN STREAM OF P-TRAP)