Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 12/19/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO CHECK GFCI AT ROOF WIRED INCORRECT, SHOWING HOT ON NEUTRAL WITH HOT OPEN 2) NEED TO PROTECT PEX LINES AT EXTERIOR WALL FROM UV AND FREEZING 3) NEED TO SEPERATE PEX LINES AT B-VENT MINIMUM 6" 4) NEED PERMANENT ADDRESS AT PANEL |
|
| 12/15/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ADDRESS ON PANEL 2) NEED TO PROTECT PLASTIC WATER LINES AT METAL ENCLOSURE 3) INSULATE WATER LINES AT WATER HEATER 4) NEED 14 GAUGE CHORD AT FURNACE 5) IN PLACE IS 16 GAUGE 6) MISSED GFCI RECEPT AT ROOF |