Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2009 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/25/2009 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) MAKE UP GROUND WIRES 2) SECURE BEAMS TO GLU LAM USING 1 1/2 X 3/16 ANGLE IRON, H2.5'S OR LAGS THRU ROOF |