Permit: T08CM03618

Parcel: 205661450

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/10/2009 FRAMING Approved IVRS - Inspection :*
08/05/2009 FRAMING Partial Approval IVRS - Inspection :*
1) FIND OUT MAX OVER CURRENT, AND MINIMUM CIRCUIT AMPACITY FOR BOTH UNITS HVAC
2) NUT ON PLATE BOLT, ?, MISSING BOLT AT (HOLDOWN) AND FIRE PLACE
3) CONDENSATE SECONDARY LINE TO OUTSIDE OVER WINDOW
4) 90 DEGREE ELBOW ON GA'S VENT PAINT ORANGE
5) NOTE: #8 ROMEX FOR RANGE IS ONLY GOOD FOR 40 AMPS USE S.E. FOR #50 AMPS
6) CONNECT EXHAUST FAN TO ROOF JACK LAUNDRY
7) COUNTER TOP RECEPT NOT ALLOWED AT OVERHANG
8) GAS PRESSURE TEST