Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM03581
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/05/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
02/03/2009 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
02/02/2009 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
01/27/2009 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF A35'S AT HEEL BLOCKS ABOVE PLATES 2) STRAIGHTEN OUT HPAHD 22 ON NORTH INTERIOR SHEARWALL 3) DBL STUDS NEEDED UNDER GIRDER RAFTERS 4) RENAIL SHEATHING AT RAFTER ENDS 5) DBL TRIMMER AND KING STUD NEEDED UNDER HEADER IN CENTER BEARING WALL AT CLOSET 6) BRACE GABLE END RAFTER IN GARAGE PER 6/DT1 7) MISSED RAFTER NAILING ON TALLEST ROOF EAST SIDE |
|
01/12/2009 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) CONTRACTOR TO PLACE PLATES FOR WALL PER CODE AND ENGINEERED SPECS FROM PREVIOUS INSPECTION |
|
01/08/2009 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) SOLE PLATE ANCHORAGE OK, EXCEPT BY WEST PATIO DOOR AND SOUTH SLIDER |
|
01/06/2009 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | IVRS - RI canceled |