Permit: T08CM03553

Parcel: 117043320


Addresses:

529 N JACOBUS AV


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T08CM03553

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/24/2009 FRAMING Approved IVRS - Inspection :*
03/23/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEM #3 NOT MET
03/19/2009 FRAMING Partial Approval IVRS - Inspection :*
1) ATTIC ACCESS NEEDS CLEARANCE RE-ROUTE PEX LINES
2) PEX WATER LINES NOT PER PLAN AT KITCHEN
3) SEAL ALL PENETRATIONS THRU MOISTURE BARRIER
03/11/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED MORE STAPLES ABOVE WINDOW AT BEDROOM #4
2) NEED STAPLES ON NORTH SIDE NEXT TO DINING ROOM WINDOW
3) SEAL AROUND CUTOUT FOR ELECTRICAL BOX SOUTH SIDE OF HOUSE
4) BLOCK MECHANICAL DUCT VENT-3 SIDES
5) FIRE SEAL ALL HOLES IN TOP PLATES (UNUSED)
6) PEX WATER LINES NOT PER PLAN
7) CHASE AT MASTER BATH NEEDS TO BE 3/4 OSB OR DBL 1/2 INCH OSB
8) PRIMARY CONDENSATE LINE NOT PER CODE