Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2010 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/09/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING SMOKE ALARM MASTER BEDROOM 2) RELOCATE SMOKE ALARMS 36" FROM FORCED AIR REGISTERS 3) 2-20 AMP CIRCUITS KITCHEN/MISSING OUTLETS KITCHEN 4) EXHAUST FAN LAUNDRY 5) MISSING CRIPPLE STUDS INT. DOORS 6) TRIMMERS INT. HEADER DOORS 7) CLEAR ATTIC ACCESS 8) PROVIDE AS BUILT TO SHOW NEW LAUNDRY NOT ON PLAN OR BUILD TO PLAN 9) CLIP KITCHEN HEADERS 10) REPAIR SPLICES KITCHEN RAFTERS 11) BEDROOM WINDOWS MUST MEET EGRESS |
|
| 09/04/2009 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) WITH INTERMEDIATES |
|
| 09/03/2009 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |