Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM03501

Parcel: 141312580

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/17/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/16/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRONT DOOR NOT MEETING ACCESSIBLE ENTRANCE PER PLAN
2) SHIM FULL PLATE WIDTH OF CENTER BEARING POINT ON 3 POINT BEARING TRUSSES
3) NO LADDER TO ACCESS ROOF
4) NAIL PROTECT ELECTRICAL CONDUIT FOR KITCHEN ISLAND AT EXTERIOR SILL PLATE
5) NAIL PROTECT PLUMBING AT EXTERIOR SILL PLATE TO CODE
6) COIL STRAP TOP PLATES WEST SIDE WHERE NOT HAVING MINIMAL DBL PLATE LENGTH
7) STHD 10'S NEEDED AT NORTH WEST CORNER
8) LTT 20 NEEDED BEDROOM CLOSET WALL (EQUIVALANT)