Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/16/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRONT DOOR NOT MEETING ACCESSIBLE ENTRANCE PER PLAN 2) SHIM FULL PLATE WIDTH OF CENTER BEARING POINT ON 3 POINT BEARING TRUSSES 3) NO LADDER TO ACCESS ROOF 4) NAIL PROTECT ELECTRICAL CONDUIT FOR KITCHEN ISLAND AT EXTERIOR SILL PLATE 5) NAIL PROTECT PLUMBING AT EXTERIOR SILL PLATE TO CODE 6) COIL STRAP TOP PLATES WEST SIDE WHERE NOT HAVING MINIMAL DBL PLATE LENGTH 7) STHD 10'S NEEDED AT NORTH WEST CORNER 8) LTT 20 NEEDED BEDROOM CLOSET WALL (EQUIVALANT) |