Permit: T08CM03470

Parcel: 11301146Z


Addresses:

1767 E PRINCE RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T08CM03470

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/06/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
04/28/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
UNABLE TO LOCATE CONTRACTOR OR WORK TO BE INSPECTED
04/14/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) BAKERY HAND SINK PIPING AND VENT CONNECTION TO EXISTING OK
04/09/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
FLOOR SINK AT SODA IS REQUIRED TO BE READILY ACCESSIBLE FOR INSPECTION AND MAINTENANCE
PER UPC 804.1
04/08/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
AT BAKERY HAND SINK
REMOVE CONCRETE FROM ABS AT FLOOR PENETRATION
SECURE TUBING IN WALL
PROVIDE TEST ON WATER AND VENT
DRAIN & VENT PIPING
ROUTE VENT TO CLOSET
RE-VENT (AAV ALLOWED W/PLAN REVISION ONLY)
03/18/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER WALLS AT STARBUCKS
NEED TO SEE TERMINATION FOR FLOOR SINK VENT
USE APPROVED STRAPS
02/19/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*