Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T08CM03470
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2009 | PLUMBING - ROUGH, SOIL | Approved | ||
03/17/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
03/16/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* STARBUCKS SOIL PIPING OK PROVIDE DRAIN CONN. FOR 3-COMP SINK OK TO WET VENT WITH 3" ABOVE FS |
|
03/12/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 4" ABS SCH40 BRANCH FROM P.O.C AT EXISTING 4" TO STARBUCKS AREA ONLY. NO PIPING IN STARBUCKS HAS BEEN INSTALLED. OK TO COVER. |
|
03/10/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. FLOOR SINK AT BAKERY UNDER SLAB ONLY 2. CORRECT BACKPITCHED SECTION OF VENT VENTS BELOW FLOOD RIM TO HAVE 1/4" PITCH 3. REQUIRE FULL SIZE CLEANOUT FOR 3" FLOOR SINK 4. 2" HAND SINK UNDER SLAB AT BAKERY OK TO COVER |
|
02/25/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* THREE FLOOR SINKS IN PRODUCE PREP AREA INSTALLED OK OK TO COVER |
|
02/24/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* FLOOR SINK IN PRODUCEOK TO COVER TEST TO TEN FEET OK P.O.C TO EXISTING OK |
|
02/19/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. FLORAL IS COMPLETE. OK TO OCCUPY SUBJECT TO BLDG. INSPECTOR 2. CWV IN PRODUCE AREA OK TO COVER |
|
02/12/2009 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ISLAND SINK VENT TAKE OFF REQUIRED TO BE A WYE PATTERN FITTING. SEE ILLISTRATED TRAINING MANUAL. COPIES GIVEN 2) INSTALL FOOT VENT CLEANOUT NOW SO THAT NO JOINT GOES UNTESTED 3) DEMOED SINK DRAIN NEEDS TO HAVE TEMP CAP TO PREVENT SEWER GASES FROM ENTERING STORE 4) FAILURE TO COMPLY WILL RESULT IN REINSPECTION FEES |
|
02/12/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) PAID AFTER HOURS INSPECTION REQUESTED BY JIM WITH DEHORTY CONTR. 2) PAID WITH MONEY GRAM 6834735999 3) JIM W/ DEHORTY 602-403-9850 4) ISLAND VENT FOR FLORAL; CORRECTIONS OK 5) ABS SLEEVE IN PLACE 6) INSTALL TEST TEES IN CORRECT DIRECTION OF FLOW 7) INSTALL FOAM WRAPS |
|
02/10/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* ADDRESS NOT POSTED - SAFEWAY FS AT CHEESE ISLAND, OK FS AT COLS. D/2 OK WRAP PIPING PENETRATING CONCRETE KEEP ALL OPEN PIPES CAPPED DURING CONSTRUCTION |