Permit: T08CM03468

Parcel: 11615082A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM03468

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/03/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
10/28/2010 PLUMBING - FINAL Not ready for Inspection 1) MISSING STRAINERS
2) HEALTH DEPT REQUIRES ADDITIONAL HAND SINK NOT SHOWN ON APROVED PLAN
3) HAND SINK IS TO BE DIRECTLY CONNECTED TO SANITARY SEWER
09/24/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES THRU NO MORE THEN 4' BETWEEN HANGERS
2) PLUMBERS TAPE NOT APPROVED
09/16/2010 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
09/15/2010 PLUMBING - FINAL Not ready for Inspection 1) NO ACCESS TO WATER HEATER
2) 3" VENT NOT CONNECTED TO EXISTING
3) SANITIZING BOWL TO DRAIN INDIRECTLY TO FLOOR SINK
4) I.W. PIPING TO BE DRAINAGE FITTINGS
5) AIR GAPS STRICTLY ENFORCED
6) OPEN TEE AT HAND SINK DRAIN
7) FINISH ICE MAKER DRAIN
09/14/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SEE NOTE #1 FROM 09/10/10
2) CONTINUED NOT READYS MAY RESULT IN A REINSPECTION FEE
09/10/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PLEASE CALL IN AND HAVE APPROVED, ALL REQUIRED INSPECTIONS PRIOR TO CALLING FINAL
2) HAVE APPROVED PLAN ON SITE
3) 3 COMP SINK MAY NOT BE INDIRECTLY WASTED
4) I.W. PIPING TO BE DRAINAGE FITTINGS
5) INSPECTOR CANNOT MAKE ADEQUATE INSPECTION WITHOUT APPROVED PLAN