Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ENGINEERING - FINAL
Permit Number - T08CM03466
Inspection Description - ENGINEERING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/09/2010 | ENGINEERING - FINAL | Approved | ||
10/06/2009 | ENGINEERING - FINAL | Partial Approval | SEE PREVIOUS NOTES | |
05/19/2009 | ENGINEERING - FINAL | Partial Approval | Contractor needs to: 1- Repair all holes in parking area. 2- Separate all construction materials, debris and activity from public access. 3- Clean all silt out of parking hot. 4- Provide HC access from all HC parking to front door. 5- All HC parking needs to be 2% max slope all directions. 6- Pin down all wheel stops. 7- Address all ponding in parking area. 8- Complete all trash enclosures. 9- Complete all fire em access, rear of building. 10- Address ponding read of building near door way. 11- Complete all striping. 12- Complete all bike parking per the approved drawings. 13- Engineer needs to addess 6" revealon all sidewalks. (DSMR) 14- Engineer need to address changes to rear of building. (DSMR) |