04/29/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CLOSET FLANGE OK
04/28/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CALL BACK FOR CLOSET FLANGES
04/14/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) CALL BACK FOR CLOSET FLANGE
04/13/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PROVIDE APPROVED PLANS FOR UNDERGROUND
2. TEST ON UNDERGROUND ON PE OK
04/10/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
04/09/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER IN WALLS TEST OK
04/08/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ABS IN EAST WALL ON NORTH SIDE BAKERY OK
04/07/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WEST SIDE WALL OK
04/02/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. WATER PIPING TEST IN WALL FOR WEST SIDE OF STORE
2. EAST WALL OF BAKERY OK ONLY
3. TEST ON ABS OK
4. ADD SUPPORT ON WATER PIPING
5. PROVIDE SUPPORT ON ALL ABS PIPING
6. OFFSET ABS AT MOP SINK
7. COMPLETE INSULATION ON WATER PIPING IN WALL
03/26/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*