Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/08/2009 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHECK ALL NAILING COMPLY WITH PREVIOUS 2) OVER SPANS THROUGHOUT/CHECK AB'S AT JOINTS 3) COMPLETE CONDUIT TO PANEL RIGID 4) TERMINATE WIRING ALL BOXES 5) WATER TEST ROOF TOP ABS POTABLE WATER OK 6) BLUE TRACER WIRE PER HOUSE BILL 2250 7) WORK NOT COMPLETE ENOUGH TO INSPECT 8) PROVIDE PLUMBING PLAN 9) INSTALL ALL RECESSED CAN LIGHTS PER PLAN TERMINATE WIRING IN CANS 10) MISSING EXTERIOR LIGHTS LIVING ROOM TERMINATE TO EXTERIOR 11) TERMINATE BATH LIGHT IN APPROVED BOX 12) TERMINATE WIRING TO EXHAUST FANS 13) SECURE 4 GANG BOXES 14) MORE DETAIL REQUIRED FOR SOFFIT, AIR HANDLER AND ATTIC ACCESS ON PLAN 15) ENGINEERING MAY BE REQUIRED |
|
| 01/07/2009 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH #1 FROM PAST 2 PREVIOUS INSPECTIONS 2) CALL FOR INTERMEDIATES AFTER EXTERIOR SHEATHING IS COMPLETED AND SIGNED OFF |
|
| 12/31/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER CONTRACTOR |
|
| 12/30/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FINISH NAILING OF T-11 2) HAVE STAMPED SET OF REVISIONS BY CITY 3) CALL AT INTERMEDIATES AFTER ELECTRICAL, HEATING AND AIR |
|
| 12/22/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHECK ALL SIDING NAILING PROVIDE 6" ON CENTER EDGE 12" FIELD 2) PROVIDE TRUSS LAYOUT SHEET 3) PROVIDE 1/2" CLEARANCE THROUGHOUT 2 POINT BEARING TRUSSES 4) PROVIDE SAFE ACCESS TO ROOF 5) PROVIDE AS BUILT CHANGE FROM 3/8" OSB WITH STUCCO SYSTEM TO T-11 SIDING WITH APPROVALS OMITON OF OVERHANG WHERE APPLIES 6) COMPLY WITH DETAIL 2/A7 EDGE NAILING DIAPHRAM WITH BLOCKING 7) PROVIDE VENTILATION DETAIL 8) X-BRACE GABLE ENDS |
|
| 12/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |