Permit: T08CM03409

Parcel: 141314780

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM03409

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/06/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/03/2009 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) SHEAR TRANSFER, TO BE ADDRESSED WITH PLAN CHANGE
02/27/2009 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE REJECTIONS FROM LAST INSPECTION, ITEMS 3,5,8,9 & 11 NOT COMPLETE
2) ROOF DRIED IN-NO REINSPECTION MADE
3) VERTICAL NAILING AT REAR H.D. AT SLIDING DOOR, MISSING
4) LETTER FROM ENGINEER DETAIL 8- CAN'T FIND IT ON MINI PLAN. IS IT ON FULL SIZE SET ?
02/25/2009 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHECK WITH ENGINEER 8 SYMBOL IS FOR A COIL STRAP, THIS SYMBOL IS ON THE CONCRETE PAGE AND SHEAR PAGE FOR 1ST FLOOR. ARE ANY H.D.'S REQUIRED OR NOT ?
2) MISSING #5 SHEAR 1ST FLOOR KITCHEN
3) NAIL ALL STUDS CONNECTED TO H.D.'S COSB-STUDS
4) <8> #8 COIL STRAPS TO CONNECT 1ST/2ND FLOOR 11 NAILS IN TOP/BOTTOM STUDS
5) SHEAR TRANSFER INTERIOR WALLS TO FLOOR
6) MISSING NUT WASHER REAR PORCH COL.
7) POINT LOAD FROM ROOF GIRDERS DBL STUD/CRIPPLE DOWN TO CONCRETE
8) FRONT COL. PLATE
9) TIE GARAGE ROOF TO WALL H2.5
10) 2ND FLOOR BOTTOM PLATES (2 RODS AT EACH FLOOR TRUSS)
11) ROOF NAIL MISSING NAILING MARKED IN BLACK, DRIVE ALL STAPLES ?, MORE NAILS IN FRIEZE BLOCKS
12) TIE TOP PLAT TO FLOOR TRUSS GARAGE WALL SO.
02/24/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CARPENTERS STILL INSTALLING