Permit: T08CM03393

Parcel: 12620001C

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/31/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
12/30/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) INSTALL BOX EXTENDERS WHERE NEEDED PER NOTES LAST INSPECTION, LEAVE DEVICE PLATES OFF TO VERIFY
12/23/2008 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1. COMPLETE INSTALLATION OF DEVICE COVER PLATES
2. INSTALL BOX EXTENDERS WHERE MORE THAN 1/4" GAP BETWEEN DRYWALL SURFACE & P-RING PER NEC
12/11/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. MC CABLE CANNOT BE SUPPORTED TO OTHER CONDUITS
2. MC CANNOT BE RUN INSIDE WALL STUD CHANNELS UNLESS A MIN. DISTANCE OF 1 1/2" BETWEEN STUD FACE & CABLE