Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM03362

Parcel: 141340270

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM03362

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/27/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/11/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LTP4'S NEEDED FOR SHEAR TRANSFER AT BACK PATIO PER ENGINEER PLAN CORRECTION
12/09/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER STEWART
12/04/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLARIFY DT1/17 AT BACK PATIO SHEAR CONNECTION FOR DRAG TRUSS
2) 6' LONG MST 48 EACH SIDE OF GARAGE OVER HEAD DOOR
3) 2 X 8 HEADER NEEDED IN GARAGE SERVICE DOOR TO EXTERIOR PER PLAN
4) DBL 2 X 8 NEEDED FOR KITCHEN DOOR
5) LATTERAL BRACE K01A, K02AP, K03AP AND K01AP
6) NAIL SHEAR PANELS THRU ROOF AT 6" ON CENTER
7) NAILS MISSING SOUTH SIDE OF ROOF IN MIDDLE