Permit: T08CM03361

Parcel: 141340140

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM03361

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/24/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/11/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST BASES NEEDED AT NORTH GARAGE WALL PER FOUNDATION PLAN #20
2) PLAN CALLS FOR 5 1/8" X 16.5 GLU LAM ? UNDER WALL OF BONUS ROOM CENTER OF GARAGE
3) LATTERAL BRACE FT08 TO RAFTER SPECS
4) SUPPORT LEDGERS FOR WATER HEATER PLATFORM
5) HEADER SIZE VERIFICATION FOR 1ST FLOOR WINDOWS WEST SIDE
6) HEADER SIZE AND NUMBER OF TRIMMERS AND KING STUDS FOR ENTERTAINMENT CENTER
7) HEADER SIZED FOR BEDROOM #4 HALLWAY
8) FLOOR TRUSS HANGER NEEDED AT BEAM FOR FT03 FLOOR TRUSS
9) VERIFICATION ON ELIMINATION OF KING STUDS IN 3 WINDOW SINGLE HEADER
10) SHEARWALL MISSING BONUS ROOM BATH SOUTH WALL