Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM03361
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/24/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
12/11/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST BASES NEEDED AT NORTH GARAGE WALL PER FOUNDATION PLAN #20 2) PLAN CALLS FOR 5 1/8" X 16.5 GLU LAM ? UNDER WALL OF BONUS ROOM CENTER OF GARAGE 3) LATTERAL BRACE FT08 TO RAFTER SPECS 4) SUPPORT LEDGERS FOR WATER HEATER PLATFORM 5) HEADER SIZE VERIFICATION FOR 1ST FLOOR WINDOWS WEST SIDE 6) HEADER SIZE AND NUMBER OF TRIMMERS AND KING STUDS FOR ENTERTAINMENT CENTER 7) HEADER SIZED FOR BEDROOM #4 HALLWAY 8) FLOOR TRUSS HANGER NEEDED AT BEAM FOR FT03 FLOOR TRUSS 9) VERIFICATION ON ELIMINATION OF KING STUDS IN 3 WINDOW SINGLE HEADER 10) SHEARWALL MISSING BONUS ROOM BATH SOUTH WALL |