Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T08CM03326
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2012 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 08/23/2012 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) RECEPTACLE COER TO BE WEATHER RESISTANT WHETHER OR NOT PLUGGED INTO 406.8 2) LABEL PANEL DIRECTORIES 408.4 3) ONLY ONE CONDUCTOR PER LUG 4) PROPERLY GROUND RECEPTACLE BOXES 5) VERIFY FAULT CURRENT TO PEISIAC 1795 W DREXEL |