Permit: T08CM03274

Parcel: 11308115C

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/28/2009 FRAMING Approved IVRS - Inspection :*
10/19/2009 FRAMING Partial Approval IVRS - Inspection :*
1) SUBMIT TRUSS CALCS FOR CITY OF TUCSON STAMP
2) OK TO INSULATE AND SHEETROCK
10/16/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING CLIPS PER DETAIL 6/A5 H2.5 DBL BEARING WALL
2) NAIL PROTECT PLUMBING POWDER ROOM 3" DRAIN AT TOP PLATES
3) PER DETAIL 8/AS.0 CC5 POST CAP AND CC66 OPPOSITE END, I WILL EXCEPT FHA COIL STRAP
4) PROVIDE 12" CLEARANCE PEX FROM CAN MASTER SHOWER
5) INSTALL TEMP GFI PANEL, TAPE ALL CONDUCTOR ENDS
6) SUBMIT TRUSS CALCS FOR APPROVAL CITY OF TUCSON