Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2009 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/19/2009 | FRAMING | Partial Approval | IVRS - Inspection :* 1) SUBMIT TRUSS CALCS FOR CITY OF TUCSON STAMP 2) OK TO INSULATE AND SHEETROCK |
|
| 10/16/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING CLIPS PER DETAIL 6/A5 H2.5 DBL BEARING WALL 2) NAIL PROTECT PLUMBING POWDER ROOM 3" DRAIN AT TOP PLATES 3) PER DETAIL 8/AS.0 CC5 POST CAP AND CC66 OPPOSITE END, I WILL EXCEPT FHA COIL STRAP 4) PROVIDE 12" CLEARANCE PEX FROM CAN MASTER SHOWER 5) INSTALL TEMP GFI PANEL, TAPE ALL CONDUCTOR ENDS 6) SUBMIT TRUSS CALCS FOR APPROVAL CITY OF TUCSON |